Solution
1. Ship
AGESTAR provides quality
marine generators ranging from 20kW to 800kW (50Hz and 60Hz range). Our marine
generator sets are assembled from the worldwide trusted brand Cummins. The
marine gensets are coupled with Stamford alternators, control panel, circuit
breaker, and steel base frame.
2. Bank
Bank, stock and securities exchange and other financial systems have a large number of advanced computers and data storages. The equipment can ensure the safety of data and capital only through stable and reliable operation, so the continuous power supply is the most important.
Product Requirements:
1. Working Environment
Not more than 1000 meters above sea level;
Operate normally from -15 ℃
to 40 ℃;
Beyond this temperature range, the special unit can be used;
The overloading for 1 hour by 10% can be made per 12 hours;
2. Noise Requirements
Ultra-low noise can ensure that bank staff set their mind on the work;
Low exhaust emissions can ensure the cleanliness of generator room;
Noise reduction measures can be developed according to different environmental
requirements;
3. Safety Measures
The unit is equipped with grounding protection and emergency shutdown button;
The unit can send sound and light alarm signals in the case of too low oil
pressure, too high water temperature, too low water level, overload, startup
failure, overspeed, short circuit, phase lack, too high voltage, voltage loss,
low frequency, too low voltage of startup battery, too high voltage of startup
battery, low oil level, etc.;
Brushless permanent magnet excitation AC generator is used to improve motor
starting bearing capacity and non-linear load capacity and provide immunity for
the waveform distortion of mainframe stator output voltage and stronger
short-circuit current withstanding capacity (usually up to 3 times of rated
current for continuous 10S);
The full automatic transfer switch cabinet can be selected according to needs;
Unit / mains switch time is not more than 20 seconds and automatic shutdown is
made after operation and cooling for 0-300s from the mains restoration;
4. Performance Guarantee
The unit uses high-end brand engines and generators, with powerful performance;
The unit MTBF is not less than 1000 hours;
Optimal design and strong environmental adaptability;
Solutions:
The AGESTAR generator set with excellent and stable performance is integrated with the advanced design concept to ensure that the alternative power supply system can quickly provide power in case of the outage of banks, which is stable and of low noise and meets European and American emission standards. The AMF function and use of ATS cabinet can meet special needs of banks. Through equipped RS232 or RS485 / 422 communication interfaces, it can be networked with the computer to make remote monitoring and achieve remote control, remote signaling and remote sensing so as to be full automatic and unattended.
Advantages of Product:
Targeted complete products, data and programs meeting the use
requirements;
Control system with AMF function can achieve automatic startup and shutdown;
ATS can be selected to achieve intelligent switching of unit / mains;
Stable performance and unit MTBF not less than 1000 hours;
The specific devices can be selected to achieve operating needs of high cold
and high temperature regions;
The design and development can be made according to special customer demands;
3. Oilfield
From the oilfield exploration to the natural gas processing and construction, operation and maintenance of oil production facilities, AGESTAR has a mature power plan. Although the oilfield is powered by the grid, the supply can not be guaranteed. The outage is often due to the season, bad weather, line fault and other causes. Therefore, diesel generator sets usually becomes necessary equipment and are primarily used to provide electric power for life, engineering and equipment transformation, which are common units.
Product Requirements:
1.Working Environment
Not more than 3000 meters above sea level;
Operate normally from -15 ℃ to 40 ℃;
Beyond this temperature range, the special unit can be used;
The overloading for 1 hour by 10% can be made per 12 hours;
2. Safety Measures
The unit is equipped with grounding protection and emergency shutdown button;
The unit can send sound and light alarm signals in the case of too low oil
pressure, too high water temperature, too low water level, overload, startup
failure, overspeed, short circuit, phase lack, too high voltage, voltage loss,
low frequency, too low voltage of startup battery, too high voltage of startup
battery, low oil level, etc.;
The full automatic transfer switch cabinet can be selected according to needs;
Unit / mains switch time is not more than 20 seconds and automatic shutdown is made
after operation and cooling for 0-300s from the mains restoration;
3. Serial and Parallel Operation Function
Serial operation backup function: It can coordinate with the ATS to achieve
automatic switching of mains and diesel generator set or dual standby switching
between two diesel generator sets.
Parallel operation and expansion function: two or more three-phase units with
the same models and specifications meet the stable running within the (20%-100%)rated power
range under the conditions of rated power factors. To improve the reasonable
distribution precision of active power and reactive power and running
stability, the diesel engine governor in the unit has the adjustable device
with the steady state governing rate from 2% to 5%. The voltage regulating
device in the control cabinet (panel) can adjust the steady state voltage
regulating factor within the range of 5%.
4. Performance Guarantee
The unit uses high-end brand engines and generators, with powerful performance;
The external fuel system can be developed and the large-capacity fuel tank
meets the operation for 12-24 hours;
Unit MTBF is not less than 1000 hours;
Optimal design and strong environmental adaptability;
Solutions:
The AGESTAR generator set with excellent and stable performance is integrated with the advanced design concept to ensure that the alternative power supply system can quickly provide power in case of the outage. Through equipped RS232 or RS485 / 422 communication interfaces, it can be networked with the computer to make remote monitoring and achieve remote control, remote signaling and remote sensing so as to be full automatic and unattended.
Advantages of Product:
Targeted complete products, data and programs meeting the
use requirements;
Control system with AMF function can achieve automatic startup and shutdown;
ATS can be selected to achieve intelligent switching of unit / mains;
Stable performance and unit MTBF not less than 1000 hours;
The specific devices can be selected to achieve operating needs of high cold
and high temperature regions;
The design and development can be made according to the special customer
demands;
4. Minefield
The power plan developed by the AGESTAR can improve operational efficiency of mining and smelting plant. The diesel generator set is often used to meet domestic consumption, engineering consumption and production consumption in the mine, which serves usually as a common unit.
Product Requirements
1.Working Environment
Not more than 3000 meters above sea level;
Operate normally from -15 ℃
to 40 ℃;
Beyond this temperature range, the special unit can be used;
The overloading for 1 hour by 10% can be made per 12 hours;
2. Safety Measures
The unit is equipped with grounding protection and emergency shutdown button;
The unit can send sound and light alarm signals in the case of too low oil
pressure, too high water temperature, too low water level, overload, startup
failure, overspeed, short circuit, phase lack, too high voltage, voltage loss,
low frequency, too low voltage of startup battery, too high voltage of startup
battery, low oil level, etc.;
The full automatic transfer switch cabinet can be selected according to needs;
Unit / mains switch time is not more than 20 seconds and automatic shutdown is
made after operation and cooling for 0-300s from the mains restoration;
3.Performance Guarantee
The unit uses high-end brand engines and generators, with powerful performance;
The external fuel system can be developed and the large-capacity fuel tank
meets the operation for 12-24 hours;
Unit MTBF is not less than 2000 hours;
Optimal design and strong environmental adaptability;
Solutions
The external refueling water system with the stable performance,
simple operation, convenient maintenance, low noise, convenient external, and
other advantages can meet special needs of the mine.
Advantages
of Product
Targeted complete products, data and programs meeting the use
requirements;
Control system with AMF function can achieve automatic startup and shutdown;
ATS can be selected to achieve intelligent switching of unit / mains;
Stable performance and unit MTBF not less than 1000 hours;
The specific devices can be selected to achieve operating needs of high cold
and high temperature regions;
The design and development can be made according to the special customer
demands;
5. Building
AGESTAR standard silent type diesel generator set can serve as the standby emergency power supply of department stores, commercial buildings, commercial residential buildings, star hotels, schools and other buildings, being mainly used to provide power required by the necessary equipment in case of mains outage.
Product Requirements:
1.Working Environment
Not more than 1000 meters above sea level
Operate normally from -15 ℃ to 40 ℃
Beyond this temperature range, the special unit can be used;
The overloading for 1 hour by 10% can be made per 12 hours;
2.Noise Requirements
Noise is proportional to the unit output power, ranging from 65 to 118db (A);
Noise reduction measures can be developed according to different environmental
requirements;
3.Safety Measures
Unit is equipped with grounding protection and emergency shutdown button;
The full automatic transfer switch cabinet can be selected according to needs;
Unit / mains switch time is not more than 20 seconds and automatic shutdown is
made after operation and cooling for 0-300s from the mains restoration;
4.Performance Guarantee
Unit uses high-end brand engines and generators, with powerful performance;
Unit MTBF is not less than 1000 hours;
Optimal design and strong environmental adaptability
Solutions:
The AGESTAR generator set with excellent and stable performance is integrated with the advanced design concept to ensure that the alternative power supply system can quickly provide power in case of the outage of main power supply, which can support normal operation of various buildings and facilities in the world.
Advantages of Product:
Targeted complete products, data and
programs meeting the use requirements;
Control system with AMF function can achieve automatic startup and shutdown;
ATS can be selected to achieve intelligent switching of unit / mains;
Stable performance and unit MTBF not less than 1000 hours;
The specific devices can be selected to achieve operating needs of high cold
and high temperature regions;
The design and development can be made according to the special customer
demands;
6. Hospital
A number of
equipments in hospitals maintain the patient vital signs, so the outage is
absolutely not allowed. Since the hospitals also have the characteristics of
necessary power supply continuity and quiet environment, there are demanding
requirements on the performance stability, AMF and ATS functions, instant
start-up time, low noise, low exhaust emission, safety and other areas of
diesel generator sets.
Product Requirements:
1. Working Environment
Not more than 1000 meters above sea level;
Operate normally from -15 ℃ to 40 ℃;
Beyond this temperature range, the special unit can be used;
The overloading for 1 hour by 10% can be made per 12 hours;
2. Noise Requirements
Ultra-low noise can meet the surgical needs and patient cultivation;
Noise reduction measures can be developed according to different environmental
requirements;
3. Safety Measures
The unit is equipped with grounding protection and emergency shutdown button;
The full automatic transfer switch cabinet can be selected according to needs;
Unit / mains switch time is not more than 20 seconds and automatic shutdown is
made after operation and cooling for 0-300s from the mains restoration;
4. Performance Guarantee
The unit uses high-end brand engines and generators, with powerful performance;
The unit MTBF is not less than 1000 hours;
Optimal design and strong environmental adaptability;
Solutions:
The AGESTAR generator set with excellent and
stable performance is integrated with the advanced design concept to ensure
that the alternative power supply system can quickly provide power in case of
the outage of main power supply, which is stable and of low noise and meets
European and American emission standards. The AMF function and use of ATS
cabinet can meet special needs of hospitals. Through equipped RS232 or RS485 /
422 communication interfaces, it can be networked with the computer to make
remote monitoring and achieve remote control, remote signaling and remote
sensing so as to be full automatic and unattended.
Advantages of Product:
Targeted complete products, data and programs
meeting the use requirements;
Control system with AMF function can achieve automatic startup and shutdown;
ATS can be selected to achieve intelligent switching of unit / mains;
Stable performance and unit MTBF not less than 1000 hours;
The specific devices can be selected to achieve operating needs of high cold
and high temperature regions;
The design and development can be made according to the special customer
demands;
7. Telecommunications
AGESTAR diesel generator set is usually used for the power generation of base station of telecommunications. The unit is subject to the provincial 1000KW-500KW and regional city 400KW-100KW with the general use of a short time and selected according to reserve capacity; it is generally as the common unit below the district and county 100KW. In addition to the self-starting, self-switching, self-running, self-input, self-shutdown, etc., such application is also equipped with various fault alarm and automatic protection devices.
Product Requirements:
1.Working Environment
Not more than 3000 meters above sea level;
Operate normally from -15 ℃ to 40 ℃;
Beyond this temperature range, the special unit can be used;
The overloading for 1 hour by 10% can be made per 12 hours;
2.Automation Function
Automatic startup and automatic loading:
The unit automatically starts after receiving self-control or remote control
startup commands, with the startup success rate of more than 99%. A startup
cycle includes three startups, with the time gas of 10-15s between two
startups; after the unit starts successfully, it shall be able to make
automatic loading when the machine oil pressure reaches the specified values
and the loading time is usually 10s; the unit no longer starts after three
startups and sends the signal of startup failure. If the standby unit is
available, the startup command shall be able to reach the standby unit.
Automatic unloading and shutdown: the unit can perform automatic unloading and
shutdown after receiving the self-control or remote control shutdown commands.
The shutdown methods include the normal shutdown and emergency shutdown. Normal
shutdown procedure: cut off the main circuit (switch off air switch or transfer
ATS to the mains side); emergency shutdown procedure: immediately cut off the
main circuit and fuel oil circuit.
Automatic protection: the unit has protections for low machine oil pressure,
overvoltage, overspeed, overload, short circuit and phase lack, the water
cooling unit gas the high-temperature protection function and the air cooling
unit has the high cylinder temperature protection function.
Low exhaust emissions ensure the air quality in the surrounding environment;
Noise reduction measures can be further developed according to different
environmental requirements;
3.Remote Monitoring Capability
Meet the technical requirements for remote monitoring and have the functions of
remote sensing, remote signaling and remote control to be able to make
real-time remote monitoring of unit operating parameters and operating state.
When the unit has unusual circumstances or serious failures, the automatic
alarm to the monitoring center and remote control of unit can be achieved. The
standard communication protocols can be provided.
4.Serial and Parallel Operation Function
Serial operation backup function: it can coordinate with the ATS to achieve
automatic switching of mains and diesel generator set or dual standby switching
between two diesel generator sets.
Parallel operation and expansion function: two or more three-phase units with
the same models and specifications meet the stable running within the (20%-100%)rated power
range under the conditions of rated power factors. To improve the reasonable
distribution precision of active power and reactive power and running
stability, the diesel engine governor in the unit has the adjustable device
with the steady state governing rate from 2% to 5%. The voltage regulating
device in the control cabinet (panel) can adjust the steady state voltage
regulating factor within the range of 5%.
5.Safety Measures
The unit is equipped with grounding protection and emergency shutdown button;
The unit can send sound and light alarm signals in the case of too low oil
pressure, too high water temperature, too low water level, overload, startup
failure, overspeed, short circuit, phase lack, too high voltage, voltage loss,
low frequency, too low voltage of startup battery, too high voltage of startup
battery, low oil level, etc.;
Brushless permanent magnet excitation AC generator is used to improve motor
starting bearing capacity and non-linear load capacity and provide immunity for
the waveform distortion of mainframe stator output voltage and stronger
short-circuit current withstanding capacity (usually up to 3 times of rated
current for continuous 10S);
The full automatic transfer switch cabinet can be selected according to needs;
Unit / mains switch time is not more than 20 seconds and automatic shutdown is
made after operation and cooling for 0-300s from the mains restoration;
Solutions:
The AGESTAR generator set with excellent and stable performance is integrated with the advanced design concept to ensure that the alternative power supply system can quickly provide power in case of the outage of communication base station. Through equipped RS232 or RS485 / 422 communication interfaces, it can be networked with the computer to make remote monitoring and achieve remote control, remote signaling and remote sensing so as to be fully automatic and unattended.
Advantages of Product:
Targeted complete products, data and programs meeting the
use requirements;
Control system with AMF function can achieve automatic startup and shutdown;
ATS can be selected to achieve intelligent switching of unit / mains;
Stable performance and unit MTBF not less than 2000 hours;
The specific devices can be selected to achieve operating needs of high cold
and high temperature regions;
The design and development can be made according to the special customer
demands;
8. Outdoor Engineering
AGESTAR outdoor engineering power plan has withstood the tests of many world-renowned projects. Through the customer reaction for years of use, AGESTAR diesel generator set is commendable by its stability, reliability, convenient use and other features.
Product Requirements:
1.Working Environment
Not more than 3000 meters above sea level;
Operate normally from -15 ℃ to 40 ℃;
Beyond this temperature range, the special unit can be used;
The overloading for 1 hour by 10% can be made per 12 hours;
2. Safety Measures
The unit is equipped with grounding protection and emergency shutdown button;
The unit can send sound and light alarm signals in the case of too low oil
pressure, too high water temperature, too low water level, overload, startup
failure, overspeed, short circuit, phase lack, too high voltage, voltage loss,
low frequency, too low voltage of startup battery, too high voltage of startup
battery, low oil level, etc.;
The full automatic transfer switch cabinet can be selected according to needs;
3.Performance Guarantee
The unit uses high-end brand engines and generators, with powerful performance;
The external fuel system can be developed and the large-capacity fuel tank
meets the operation for 12-24 hours;
Unit MTBF is not less than 2000 hours;
Optimal design and strong environmental adaptability;
Solutions:
The external refueling water system with the stable performance, simple operation, convenient maintenance, low noise, convenient external and other advantages can meet special needs of the mine.
Advantages of Product:
Targeted complete products, data and programs meeting the
use requirements;
Control system with AMF function can achieve automatic startup and shutdown;
ATS can be selected to achieve intelligent switching of unit / mains;
Stable performance and unit MTBF not less than 2000 hours;
The specific devices can be selected to achieve operating needs of high cold
and high temperature regions;
The design and development can be made according to the special customer
demands;